Position | Distance from the lampa | Angleb | Expected irradiance from nominal data | Irradiation time corresponding to expected irradiance | Measured irradiancec | Irradiation time corresponding to measured irradiance | Time required to compensate for the emission not immediately fully operational | Total irradiation time corresponding to measured irradiance | Difference between measured and expected time |
---|---|---|---|---|---|---|---|---|---|
 | [m] | [°] | [μWatt/cm2] | [s] | [μWatt/cm2] | [s] | [s] | [s] |  |
CT bed - Mobile support equipped with an AirZingâ„¢ PRO5040 lamp | |||||||||
 Side edge of the bed | 0.90 | 20 | 165 | 224 | 160 | 231 | 19 | 250 | 10.4% |
 Headrest | 1.40 | 45 | 71 | 521 | 46 | 804 | 17 | 821 | 36.6% |
Cubicle for nasopharyngeal swab - Mobile support equipped with two AirZingâ„¢ PRO5040 lamps | |||||||||
 Medical chair | 0.85 | 20 | 199 | 187 | 191 | 194 | 17 | 211 | 11.4% |
 Side edge of the bed | 1.30 | 30 | 83 | 446 | 74 | 500 | 18 | 518 | 13.9% |
Waiting room for COVID-19 triage - Two Deluxe110 lamps on the ceilingd | |||||||||
 First chair | 1.90 | 0 | 166 | 223 | 196 | 189 | 10 | 199 | −12.1% |
 Second chair | 2.60 | 45 | 89 | 416 | 89 | 416 | 9 | 425 | 2.1% |
Waiting room for COVID-19 triage - Two AirZingâ„¢ PRO5040 lamps on the ceilingd | |||||||||
 First chair | 1.90 | 0 | 39 | 949 | 42 | 881 | 18 | 899 | −5.6% |
 Second chair | 2.60 | 45 | 21 | 1762 | 13 | 2846 | 17 | 2863 | 38.5% |
Waiting room for COVID-19 triage - Two Sterilight-S72-UV-C lamps on the ceilingd | |||||||||
 First chair | 1.90 | 0 | 61 | 607 | 109 | 339 | 13 | 352 | −72.4% |
 Second chair | 2.60 | 45 | 33 | 1121 | 30 | 1233 | 13 | 1246 | 10.0% |
Waiting room for COVID-19 triage - Two Deluxe110 lamps on the wallsd | |||||||||
 First chair | 2.30 | 0 | 113 | 327 | 139 | 266 | 10 | 276 | −18.5% |
 Second chair | 4.60 | 45 | 28 | 1321 | 28 | 1321 | 9 | 1330 | 0.7% |